Micrologic 6.0h manual

 

 

MICROLOGIC 6.0H MANUAL >> DOWNLOAD LINK

 


MICROLOGIC 6.0H MANUAL >> READ ONLINE

 

 

 

 

 

 

 

 











 

 

Figure 1 - Micrologic Trip Unit. Trip Unit: Micrologic Series B LSIG w/ Alarm Voltage: 600V Max Interrupting Capacity: 100kAIC. 100 - 600 amps unmatched system coordination the micrologic в® line of moulded case circuit breakers uses electronic trip technology to provide flexibility and coordination in system circuit protec-tion. • 48049-330-03—Micrologic 5.0H and 6.0H Electronic Trip Units Manual switch to turn the ERMS setting ON/OFF. NOTE: Trip unit in ERMS mode when lit. 24 Vdc (+/-) Ethernet ULP OPT - L1/L OPT - L2/N. NHA999570 I-Line™ Smart Cell Installation 11/2015 Communications Package Accessory and Control Wiring • Bulletin 48049-330-03: Micrologic 5.0H and 6.0H Electronic Trip Units • Bulletin 48049-137-05: Micrologic 5.0P and 6.0P Electronic Trip Unit • All instructions in this manual are written with the assumption that the customer has taken these measures before performing maintenance MicroLogic 6.0H LSIG functions, M+P+H. Toggle menu. 1-800-421-5082 Search. Reset Search A full function test kit, the Square D by Schneider S33595 Secondary Injection Test Set is designed to perform tests on Micrologic, NT and STR Trip units. The Square D S33595 consists of a signal-injection box which can be used alone or with a supporting personal computer (PC). The optional test kit software is compatible with Windows® 95, 98 - Micrologic 6.0A, 6.0P, 6.0H The Full-function Test Kit (FFTK) supports testing of a wide variety of trip units in Masterpact® NW/NT, Powerpact® and Compact® circuit breakers Includes Integrated Hard Carrying Case & Accessories As Listed FFTK FF TK FF-TK Schneider current curves when performing manual test. 1. Incorrect trip unit settings entered. 2. Fault type selection (LSIG) set to instantaneous when type of fault to be tested is long-time or short- MICROLOGIC 6.0H or MICROLOGIC 6.0P trip unit does not trip when performing ground-fault test. 1. Fault level injected not high enough to cause trip on All Masterpact circuit breakers are equipped with a Micrologic control unit that can be changed on site. Control units are designed to protect Power circuits and loads. Alarms may be programmed for remote indications. Mic 5.0H: Micrologic 6: selective and . earth-fault protection. Mic 6.0: Mic 6.0A: Mic 6.0E: Mic 6.0D: Mic 6.0P: Mic 6.0H Micrologic 6.0P Trip Unit The Micrologic 6.0P trip unit provides selective and ground-fault protection for equipment (≤ 1200 A) (LSIG) and power measurement. more 600 Volts, 3 pole. Both type of circuit breakers: •provide overload and short-circuit protection. Powerpact P, R, and Masterpact NW, NT Micrologic™ 5.0H and 6.0H Trip Units, see 48049-330-03 For troubleshooting help, consult instruction manuals to ensure proper installation and review troubleshooting help sections where applicable. Attachment(s): 0613CT0001 7-15.pdf (PDF,18.3MB) SQD MICROLOGIC 6.0H SOLID STATE PROGRAMMER LSIG UNUSED SURPLUS WITH METERING, ADVANCED PROTECTION, HARMONIC ANALYSIS MANUFACTURER Square D MANUFACTURER PART NUMBER S174A-ERMS NOTES: RATING PLUG SOLD SEPERATELY When replacing a basic trip unit with type A (Ammeter), P (Power metering) or H (Harmonic analysis) Micrologic control units 5.0 H, 6.0 H and 7.0 H Low Voltage Products User manual Firmware version H Logic-2002 AAE60439A We do more with electricity. 1Micrologic H Schneider Electric Discovering Micrologic H 4 Micrologic control units 5.0 H, 6.0 H and 7.0 H Low Voltage Products User manual Firmware version H Logic-2002 AAE60439A We do mor

Comment

You need to be a member of Iconada.tv 愛墾 網 to add comments!

Join Iconada.tv 愛墾 網

愛墾網 是文化創意人的窩;自2009年7月以來,一直在挺文化創意人和他們的創作、珍藏。As home to the cultural creative community, iconada.tv supports creators since July, 2009.

Videos

  • Add Videos
  • View All